WindO/I-NV4 User’s Manual 4-45
3 Project Settings Dialog Box
4
Project Settings
When USB1(USB-A) or USB2(USB-A) is selected under Interface Configuration
*4 HG2J-7U only
Function: Selects the function used by the USB interface (Type A) from the following.
N/A, User Communication 1, User Communication 2, User Communication 3,
Wireless LAN
*4
, Speaker
*4
Access Point Setting: Configures the target access point to connect from MICRO/I via wireless LAN.
These options can only be configured when Wireless LAN is selected for Function.
Network Name (SSID): Enters the name (SSID) of the target access point. The network
name (SSID) is 1 to 32 characters.
Security Type: WPA2-PSK
Password: Enter a password. The password is 8 to 64 characters. Only
alphanumeric characters and symbols can be used.
Show Password:
Select this check box to display the characters
entered in Password. When this check box is cleared,
the passwords are displayed with * (asterisk).
IP Settings: Configure the IP address and subnet mask of the access point of the target. These options can
only be configured when Wireless LAN is selected for Function.
IP Address: Specifies the IP address. (Default: 192.168.0.150)
The format is “xxx.xxx.xxx.xxx”. “xxx” stands for a numeric value
from 0 to 255.
When connecting multiple devices to the same network, make sure to
assign each device a unique IP address.
Subnet Mask: Specifies the subnet mask. (Default: 255.255.255.0)
The format is “xxx.xxx.xxx.xxx”. “xxx” stands for a numeric value
from 0 to 255.
This value must be the same for all devices.
Port Number
:
Specifies the TCP port number (1 to 65535) to use for maintenance
communication. (Default: 2537)
Forbid Maintenance Communication:
Select this check box to prohibit maintenance communication via
wireless LAN communication.
Regarding TCP port number of MICRO/I, note the following points.
The numbers that cannot be used: • 2539: Maintenance communication (Data Transfer)
• 2538: For pass-through
• 2101: For FC4A Series MicroSmart direct connection pass-through
Duplicate numbers cannot be configured in the following functions:
• Maintenance communication
( refer to “Port Number” on page 4-41)
• Web server function ( refer to “Port Number” on page 4-67)
• FTP server function ( refer to “Port Number” on page 4-68)
• TCP Server is selected for the User Communication
( refer to “Port No.” on page 4-43)
• Modbus as Manufacture and Modbus TCP Server as
Communication Driver are selected on the Communication
Driver tab
( refer to the WindO/I-NV4 External Device Setup Manual)