6/02
6-36
DC1632/2240
Prelaunch Training/Review
General Procedures and Information
753-xxx ProCon 2 NVM List
752-455 VBias [C] 887 0~1023 DC VBias value
752-456 VBias [K] 887 0~1023 DC VBias value
752-474 Flag Empty Detection Status [Y] 0 0~3 Flag of Empty status (0 = Normal 1 = In Empty Count 2 = Near Empty 3 = End)
752-475 Flag Empty Detection Status [M] 0 0~3 Flag of Empty status (0 = Normal 1 = In Empty Count 2 = Near Empty 3 = End)
752-476 Flag Empty Detection Status [C] 0 0~3 Flag of Empty status (0 = Normal 1 = In Empty Count 2 = Near Empty 3 = End)
752-477 Flag Empty Detection Status [K] 0 0~3 Flag of Empty status (0 = Normal 1 = In Empty Count 2 = Near Empty 3 = End)
752-496 Nominal value for NEAR Detection [Y] 625 0~32767 Count threshold for Near Detection
752-497 Nominal value for NEAR Detection [M] 625 0~32767 Count threshold for Near Detection
752-498 Nominal value for NEAR Detection [C] 625 0~32767 Count threshold for Near Detection
752-499 Nominal value for NEAR Detection [K] 625 0~32767 Count threshold for Near Detection
752-784 Fail Disp Unusual [Y] 0 0~1 Fail when new Toner Cartridge is installed and the Disp Motor Drive did not shift from new to old.
0 = Normal; 1 = Error
752-785 Fail Disp Unusual [M] 0 0~1 Fail when new Toner Cartridge is installed and the Disp Motor Drive did not shift from new to old.
0 = Normal; 1 = Error
752-786 Fail Disp Unusual [C] 0 0~1 Fail when new Toner Cartridge is installed and the Disp Motor Drive did not shift from new to old.
0 = Normal 1 = Error
752-787 Fail Disp Unusual [K] 0 0~1 Fail when new Toner Cartridge is installed and the Disp Motor Drive did not shift from new to old.
0 = Normal 1 = Error
752-788 Min PV Threshold 3 0~255 Minimum PV from Near empty to empty (M/Cstop)
752-804 DispTime Totalizing value for age Cor-
rection [Y]
0 0~4294967295 Cumulative dispense time for deterioration correction of ATC Control nominal value. Set to 0 at replacement of
Developer.
752-805 DispTime Totalizing value for age Cor-
rection [M]
0 0~4294967295 Cumulative dispense time for deterioration correction of ATC Control nominal value. Set to 0 at replacement of
Developer.
752-806 DispTime Totalizing value for age Cor-
rection [C]
0 0~4294967295 Cumulative dispense time for deterioration correction of ATC Control nominal value. Set to 0 at replacement of
Developer.
752-807 DispTime Totalizing value for age Cor-
rection [K]
0 0~4294967295 Cumulative dispense time for deterioration correction of ATC Control nominal value. Set to 0 at replacement of
Developer.
752-814 Pre Near EMP Factor 80 0~255 Factor correcting [Near Detection Nominal Value] after Pre Near is displayed.
Table 12 Chain 752
Chain-Link Name Default Range Description
Table 13 Chain 753
Chain-Link Name Default Range Description
753-001 ADC Tone Correction Switch 0 0~1 [2P TRC] 2 Patch ADC Gradation CorrectiON. ON/Off Switch (0=On, 1=Off)
753-002 IOT Manual ADJ LUT Switch 0 0~1 [2P TRC] IOT Manual Adjustment LUT On/Off Switch (0=On, 1=Off)
753-004 P LUTCin [K] [E] 1 0~255 [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
753-005 P LUTCin [K] [C] 34 0~255 [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
753-006 P LUTCin [K] [A] 77 0~255 [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
753-007 P LUTCin [K] [B] 134 0~255 [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
753-008 P LUTCin [K] [D] 255 0~255 [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
753-009 P LUTCin [Color] [E] 1 0~255 [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.
753-010 P LUTCin [Color] [C] 51 0~255 [2P TRC] P LUTCin (fixed number) when the Delta LUT is calculated.