6/02
6-73
DC1632/2240
dC330
General Procedures and Information
Prelaunch Training/Review
005-081 Exit Motor Non
CVT Mode
Operate the DADF Exit Motor -
005-083 Doc Ready switch ON the Doc Ready signal. -
005-084 Doc Set LED switch ON the DOC SET LED -
006-002 IIT Exposure Lamp switch the Lamp ON for 180sec -> Auto
OFF
-
006-004 IPS Cooling Fan
(Low speed)
After operating the IPS Cooling Fan at high
speed for 5sec, operate it at low speed.
ON: FAN ON: 24V, FAN Slow: L->H (About
13V)
-
006-005 IIT Scan Motor
(Scan)
More it 50mm from current position in Scan
direction -> Auto OFF
006-006
006-006 IIT Scan Motor
(Return)
More it 50mm from current position in
Return direction -> Auto OFF
006-005
006-014 IPS Cooling Fan
(High speed)
Operate the IPS Cooling Fan at high
speed.
-
006-030 LD ON Enable Sig-
nal (concurrently
for 4 colors)
[Operation Description]: -
006-031 Polygon Motor
Start Signal
[Operation Description]: -
006-086 IIT Image Area IMG-AREA Signal Output ON: P727 LVDS
(Differential) High
-
006-091 Exchange To ADF Turn ON the document exchange com-
mand signal to the DADF
-
007-003 SMH FEED Clutch [Operation Description]: -
007-004 HOTLINE_TRAY Not used. -
008-001 #1Feed Motor
(Fwd)
Feed (Rotate #1Feed Motor in paper feed
direction at 200mm/sec)
8-002
008-002 #1Feed Motor
(Rev)
It turns OFF automatically 6sec after LiftUp
has started, or when the Level Snr detected
LiftUp. LiftUp cannot be performed when
the Level Snr should detect LiftUp.
8-001
008-003 #2Feed Motor
(Fwd)
Feed (Turn #2Feed Motor On in paper feed
direction at 192mm/sec)
8-004
008-004 #2Feed Motor
(Rev)
It turns OFF automatically 6sec after LiftUp
has started, or when the Level Snr detected
LiftUp. LiftUp cannot be performed when
the Level Snr should detect LiftUp.
8-003
008-005 #3Feed Motor
(Fwd)
Feed (Turn #3Feed Motor On in paper feed
direction at 192mm/sec)
008-006 #3Feed Motor
(Rev)
It turns OFF automatically 6sec after LiftUp
has started, or when the Level Snr detected
LiftUp. LiftUp cannot be performed when
the Level Snr should detect LiftUp.
8-005
Table 2 Output Component Control Codes
Code Name Description Conflicts
008-007 #4Feed Motor
(Fwd)
Feed (Turn #4Feed Motor On in paper feed
direction at 192mm/sec)
8-008
008-008 #4Feed Motor
(Rev)
It turns OFF automatically 6sec after LiftUp
has started, or when the Level Snr detected
LiftUp. LiftUp cannot be performed when
the Level Snr should detect LiftUp.
8-007
008-009 Dup Motor
(200.1mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-010, 011,
012, 053, 054,
055, 056
008-010 Dup Motor
(104mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-009, 011,
012, 053, 054,
055, 056
008-011 Dup Motor
(200.1mm/sec)
Long
[Operation Description]: 8-009, 010,
012, 053, 054,
055, 056
008-012 Dup Motor
(104mm/sec) Long
[Operation Description]: 8-009,
010,011, 053,
054, 055, 056
008-021 3TM TA Motor
(52mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-022, 023,
024, 025, 026,
027, 028
008-022 3TM TA Motor
(104mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-021, 023,
024, 025, 026,
027, 028
008-023 3TM TA Motor
(192mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-021, 022,
024, 025, 026,
027, 028
008-024 3TM TA Motor
(370mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-021, 022,
023, 025, 026,
027, 028
008-025 3TM TA Motor
(52mm/sec) Long
[Operation Description]: 8-021, 022,
023, 024, 026,
027, 028
008-026 3TM TA Motor
(104mm/sec) Long
[Operation Description]: 8-021, 022,
023, 024, 025,
027, 028
008-027 3TM TA Motor
(192mm/sec) Long
[Operation Description]: 8-021, 022,
023, 024, 025,
026, 028
008-028 3TM TA Motor
(370mm/sec) Long
[Operation Description]: 8-021, 022,
023, 024, 025,
026, 027
008-029 TTM TA Motor
(52mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-030, 031,
032, 033, 034,
035, 036
Table 2 Output Component Control Codes
Code Name Description Conflicts