6/02
6-74
DC1632/2240
dC330
Prelaunch Training/Review
General Procedures and Information
008-030 TTM TA Motor
(104mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-029, 031,
032, 033, 034,
035, 036
008-031 TTM TA Motor
(192mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-029, 030,
032, 033, 034,
035, 036
008-032 TTM TA Motor
(370mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-029, 030,
031, 033, 034,
035, 036
008-033 TTM TA Motor
(52mm/sec) Long
[Operation Description]: 8-029, 030,
031, 032, 034,
035, 036
008-034 TTM TA Motor
(104mm/sec) Long
[Operation Description]: 8-029, 030,
031, 032, 033,
035, 036
008-035 TTM TA Motor
(192mm/sec) Long
[Operation Description]: 8-029, 030,
031, 032, 033,
034, 036
008-036 TTM TA Motor
(370mm/sec) Long
[Operation Description]: 8-029, 030,
031, 032, 033,
034, 035
008-037 Regi Clutch Turns ON. Turns OFF automatically at
400msec.
None
008-038 #1TA Clutch Turns ON. Turns OFF automatically at
400msec.
None
008-042 Invert Clutch CW Turns ON in output direction. Turns OFF
automatically at 400msec.
None
008-043 Invert Clutch CCW Turns ON in Invert direction. Turns OFF
automatically at 400msec.
None
008-045 Exit Gate Solenoid Turns ON in output direction. Turns OFF
automatically at 200msec.
None
008-046 Dup Gate Solenoid Turns ON in Face Up direction. Turns OFF
automatically at 200msec.
None
008-047 TTM TM Motor2
(370mm/sec)
Start operation. Turns OFF automatically at
1000msec.
None
008-048 TTM TM Motor2
(370mm/sec) Long
[Operation Description]: None
008-049 MOB2LED_CHNG MOB SNR2 LED Light quantity switching
signal, Light quantity UP (increase voltage)
at PORT H. ON: ANA Output LED2 Light
quantity UP
None
008-050 OB2LED_ON MOB SNR2 LED ON. ON: ANA output None
Table 2 Output Component Control Codes
Code Name Description Conflicts
008-051 MOB1LED_CHNG MOB SNR1 LED Light quantity switching
signal, Light quantity UP (increase voltage)
at PORT H. ON: ANA Output LED1 Light
quantity UP
None
008-052 MOB1LED_ON MOB SNR1 LED ON. ON: ANA output None
008-053 Dup Motor
(373.2mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-009, 010,
011, 012, 054,
055, 056
008-054 Dup Motor
(194mm/sec)
Start operation. Turns OFF automatically at
1000msec.
8-009, 010,
011, 012, 053,
055, 056
008-055 Dup Motor
(373.2mm/sec)
Long
[Operation Description]: 8-009, 010,
011, 012, 053,
054, 056
008-056 Dup Motor
(194mm/sec) Long
[Operation Description]: 8-009, 010,
011, 012, 053,
054, 055
009-001 #Y_Disp MOT_Y Y Color Disp. MOT turns ON, and turns
OFF automatically after 5sec.
-
009-002 #M_Disp MOT M Color Disp. MOT turns ON, and turns
OFF automatically after 5sec.
-
009-003 #C_Disp MOT C Color Disp. MOT turns ON, and turns
OFF automatically after 5sec.
-
009-004 #K_Disp MOT K Color Disp. MOT turns ON, and turns
OFF automatically after 5sec.
-
009-005 #Y_DB DC Y Color Developer Bias DC Component
Output
-
009-006 #M_DB DC M Color Developer Bias DC Component
Output
-
009-007 #C_DB DC C Color Developer Bias DC Component
Output
-
009-008 #K_DB DC K Color Developer Bias DC Component
Output
-
009-009 #YM_DB AC YM Color Developer Bias AC Component
Output
-
009-012 #CK_DB AC CK Color Developer Bias AC Component
Output
-
009-013 Deve_CL The clutch for driving K Color turns ON,
and turns OFF automatically after 5sec.
-
009-014 Deve_MOT Nor-
mal-speed
The MOT for driving Color turns ON at nor-
mal speed and turns OFF automatically
after 5sec.
9-16
009-016 Deve_MOT Half-
speed
The MOT for driving Color turns ON at
higher speed and turns OFF automatically
after 5sec.
9-14
Table 2 Output Component Control Codes
Code Name Description Conflicts