3-240 Phaser 7500 Printer Service Manual
Error Messages and Codes
RC Data Over Flow Fail
The correction setting value of calculation result has exceeded the settable range.
Applicable Chain-Link Code
089-616: RC Data Over Flow Fail
Initial Actions
Power cycle the printer.
If the problem persists, follow the procedure below.
Note
When multiple failures with Chain No. 089 occur, take action according to the
priority order.
Troubleshooting Reference
Applicable Parts Wiring and Plug/Jack Map References
LPH Unit (Y, M, C, K), PL2.1.2
Troubleshooting Procedure
Step Actions and Questions Yes No
1 Raise/lower the LPH (Y, M, C, K) 2 to
3 times to check the LPH lift up/
down mechanism.
Is the problem repaired?
Troubleshooting
complete.
Replace the
LPH Unit
(REP 2.1,
page 8-18).