3-240 Phaser 7500 Printer Service Manual
Error Messages and Codes
RC Data Over Flow Fail
The correction setting value of calculation result has exceeded the settable range.
Applicable Chain-Link Code
• 089-616: RC Data Over Flow Fail
Initial Actions
• Power cycle the printer.
• If the problem persists, follow the procedure below.
When multiple failures with Chain No. 089 occur, take action according to the
priority order.
Troubleshooting Reference
Applicable Parts Wiring and Plug/Jack Map References
■ LPH Unit (Y, M, C, K), PL2.1.2
Troubleshooting Procedure
Step Actions and Questions Yes No
1 Raise/lower the LPH (Y, M, C, K) 2 to
3 times to check the LPH lift up/
down mechanism.
Is the problem repaired?
Troubleshooting
complete.
Replace the
LPH Unit
(REP 2.1,
page 8-18).