Loading...
High-level Data Link Control
Left running head:
Chapter name (automatic)
310
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Configuration Guide
Alcatel-Lucent
T
O CONFIGURE HDLC KEEPALIVE INTERVAL
Enter this command in the Interface Configuration mode.
E
XAMPLE
The following example sets the keepalive interval to 12:
ALU(config-if Serial0/0:0)# hdlc keepalive 12
T
O ENABLE LOOPBACK DETECTION
EXAMPLE
ALU(config-if Serial0/0:0)# no hdlc down-when-looped
Command (in ICM) Description
hdlc keepalive <0-32767> This command configures the HDLC
keepalive interval. The same value shall
be configured on the peer.
A value of ‘0’ turns off the keepalive
feature.
no hdlc keepalive This command resets the keepalive
interval to its default.
The default keepalive interval is 10
seconds.
Command (in ICM) Description
hdlc down-when-looped This command is used to bring down the
line protocol when loopback is detected
on the interface.
no hdlc down-when-looped This command disables bringing down of
the line protocol when loopback is
detected on the interface. This is the
default behavior.