EasyManua.ls Logo

Alcatel-Lucent OmniAccess 5740 - Page 368

Alcatel-Lucent OmniAccess 5740
1225 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Point-to-Point Protocol
Left running head:
Chapter name (automatic)
342
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Configuration Guide
Alcatel-Lucent
T
O SET TIMEOUT MAX-CONFIGURE
E
XAMPLE
ALU(config-if Serial0/0:0)# ppp timeout max-configure 15
ALU(config-if Serial0/0:0)# no ppp timeout max-configure
T
O SET TIMEOUT MAX-FAILURE
E
XAMPLE
ALU(config-if Serial0/0:0)# ppp timeout max-failure 10
ALU(config-if Serial0/0:0)# no ppp timeout max-failure
Command (in ICM) Description
ppp timeout max-configure <1-30> This command sets the maximum
number of configure request packets
(LCP or NCP) sent without receiving a
valid Ack/NaK/Reject, before
assuming that the peer is unable to
respond.
no ppp timeout max-configure The “no” command sets the max-
configure value to its default.
The default max-configure value is
“10”.
Command (in ICM) Description
ppp timeout max-failure <1-30> This command sets the maximum
number of configure NaK packets (LCP
or NCP) sent without sending a
Configure Ack before assuming that
configuration is not converging.
no ppp timeout max-failure The “no” command sets the max-failure
value to its default.
The default max-failure value is “5”.

Table of Contents

Other manuals for Alcatel-Lucent OmniAccess 5740

Related product manuals