Multilink Frame Relay
Left running head:
Chapter name (automatic)
392
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Configuration Guide
Alcatel-Lucent
T
O CONFIGURE HELLO INTERVAL
Hello interval is the duration in seconds between successive hello messages sent.
E
XAMPLE
ALU(config-if Serial0/0:0)# mlfr hello-interval 15
ALU(config-if Serial0/0:0)# no mlfr hello-interval 15
T
O CONFIGURE THE ACKNOWLEDGE INTERVAL
Acknowledge interval is the duration (in seconds) that the bundle link waits for a
hello message from its peer, or the duration it waits before resending the hello
message.
E
XAMPLE
ALU(config-if Serial0/0:0)# mlfr ack-interval 5
ALU(config-if Serial0/0:0)# no mlfr ack-interval 5
Command (in ICM) Description
mlfr hello-interval <1-180> This command configures the hello
interval. The range of this interval is from
1 to 180 seconds.
no mlfr hello-interval <1-180> This command resets the hello interval
to its default value, i.e., 10 seconds.
Command (in ICM) Description
mlfr ack-interval <1-10> This command configures the
acknowledge interval. The range of this
interval is from 1 second to 10 seconds.
no mlfr ack-interval <1-10> This command resets the acknowledge
interval to its default, i.e., 4 seconds.