Management Plane Overview
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
57
Alcatel-Lucent
Beta Beta
OmniAccess 5740 Unified Services Gateway CLI Configuration Guide
EXAMPLE
ALU(config)# traceroute
Enter the Target IP address:2.2.2.12
Enter the Source IP Address:
Enter the source interface:
Enter the Datagram Size[38]:
Enter the Timeout value[2]:
Enter the Probecount[3]:
Enter the Minimum TTL[1]:
Enter the Max TTL[30]:
Enter the Destination Port[33434]:
Enter the TOS value[0x0]:
Set the df-bit value[n]:
traceroute to 2.2.2.12 (2.2.2.12), 30 hops max, 38 byte
packets.
1 2.2.2.12 (2.2.2.12) 3.151 ms * 2.2.2.12 (2.2.2.12)
4.089 ms
Enter the TOS value[0]: Specify the Type of Service (ToS) value
in the range 0-255.
The requested ToS is placed in each
probe, but there is no guarantee that all
routers process the ToS. It is the Internet
service's quality selection.
The default is 0.
Set the df-bit value[n]: Specify whether or not the Don't
Fragment (DF) bit is to be set on the ping
packet.
If yes is specified, the Don't Fragment
option does not allow this packet to be
fragmented when it has to go through a
segment with a smaller Maximum
Transmission Unit (MTU), and you will
receive an error message from the
device that wanted to fragment the
packet. This is useful for determining the
smallest MTU in the path to a
destination. The default is no.
Field Description