firmware-on-plug
Result
The firmware is stored on the PLUG.
When the device starts up there is a check whether the version on the PLUG is valid and
whether this version matches the version on the device. If this is not the case, the firmware is
installed on the device and it is restarted. This means that automatic firmware updates/
downgrades can be made with the PLUG.
Further notes
You disable this setting with the no firmware-on-plug command.
5.1.3.3 no firmware on plug
Description
With this command, you disable the function. The firmware is removed from the PLUG.
Requirement
There is a device configuration on the PLUG.
You are in the Plug Configuration mode.
The command prompt is:
cli(config-plug)#
Syntax
Call the command without parameters:
no firmware-on-plug
Result
The firmware is removed from the PLUG.
5.1.3.4 write
Description
With this command, you format the PLUG and copy the current device configuration to it.
Functions specific to SCALANCE
5.1 PLUG
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
112 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals