8.1.2.4 no ip echo-reply
Description
With this command you stop the network node reacting to ping queries.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no ip echo-reply
Result
"ICMP echo reply messages" are disabled. The network node does not react to ping queries.
Further notes
You change the setting with the ip echo-reply command.
8.1.2.5 ip route
Description
With this command, you configure a static entry in the IP routing table.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ip route <gateway>