Syntax
Call up the command with the following parameters:
ip access-group <access-list-number(1-20)> {in|out}
The parameters have the following meaning:
Parameter Description Range of values / note
access-list-
number
Number of the access control list 1 ... 20
in Specifies that incoming packets are fil‐
tered
-
out Specifies that outgoing packets are fil‐
tered
-
Note
Restrictions when filtering layer 2 interfaces
The filtering of outgoing packets is not supported on layer 2 interfaces.
Filtering on a layer 2 interface using an IP access control list is only effective for IP packets.
To filter packets with other data formats, use an expanded MAC access control list.
Result
The packets are filtered according to the access control list (ACL).
Further notes
You disable the setting with the no ip access-group command.
You display the configuration of the access control list with the show access-lists
command.
11.5.3.2 no ip access-group
Description
With this command, you disable the access control of the packets of an interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Security and authentication
11.5 IP access control list
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
558 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals