EasyManuals Logo

Siemens SCALANCE W770 Series User Manual

Siemens SCALANCE W770 Series
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #597 background imageLoading...
Page #597 background image
cli(config-events)#
Syntax
Call up the command with the following parameters:
no link {up|down}
The parameters have the following meaning:
Parameters Description Range of values / note
up The message when establishing a connection is dis‐
abled
-
down The message when a connection is down is disabled -
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the show events faults config command.
You enable the function with the link command.
12.1.6.8 power
Description
With this command, you configure and activate the monitoring of the power supplies.
Depending on the hardware variant there are one or two power connectors (L 1 / L 2) and a
PoE power supply.
Note
This command is not available on the SCALANCE W786-2 SFP.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
power [{l1 | l2 | poe}]
Diagnostics
12.1 Diagnostics
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 597

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications