cli> or cli#
Syntax
Call the command without parameters:
show ipv6 static route
Result
The static routes are displayed.
8.2.2.5 show ipv6 traffic
Description
This command shows the statistics for UDP and ICMPv6 for the corresponding interface.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
show ipv6 traffic [
interface { vlan <vlan-id> | <interface-type> <interface-id> }
] [hc]
The parameters have the following meaning:
Parameter Description Range of values / note
interface Keyword for the interface via which the statistics
are created.
VLAN
Interface
-
vlan Keyword for a VLAN -
vlan-id Keyword for a VLAN connection 1 ... 4094
interface-
type
Type or speed of the interface Enter a valid interface.
interface-
id
Module no. and port no. of the interface
hc Display of the High counters parameter -
Network protocols
8.2 IPv6 protocol
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 361

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals