Requirement
The transmission standard 802.11g or 802.11a is set.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan fragmentation threshold <bytes(256-2346)>
The parameter has the following meaning:
Parameters Description Range of values / note
bytes Packet size in bytes 256...2346
Default: 2346
Result
The packet size is specified.
Further notes
You configure the transmission standard with the wlan mode command.
You display the setting with the show wlan advanced <wlan 0/X> command.
7.1.5.49 wlan frequency band (access point)
Description
With this command, you specify the frequency band for the WLAN interface.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 251

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals