cli(config-wlan)#
Syntax
Call up the command with the following parameters:
wlan ipcf-mc protocol-support {pnio | ethernet-ip}
Parameter Description Range of values / note
pnio Keyword for the PROFI‐
NET
ethernet-ip Keyword for the Ether‐
Net/IP
Result
The optimized support of PROFINET or Ethernet/IP is enabled.
Further notes
You display the setting with the show wlan ipcf-mc command.
5.6.2.4 wlan ipcf-mc cycle-time (access point)
Note
The command is only available if the SCALANCE W700 device supports iPFC-MC or the
function can be enabled.
iPCF-MC is enabled with the aid of the following KEY-PLUGs:
W780 iFeatures (MLFB 6GK5 907-8PA00)
W740 iFeatures (MLFB 6GK5 907-4PA00)
Description
With this command, you configure the cycle time for iPCF-MC.
Requirement
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call up the command with the following parameters:
Functions specific to SCALANCE
5.6 iPCF-MC
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 143

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals