7.1.5.27 wlan data rates-11abg selected only (access point)
Description
With this command, you enable the "Use selected data rates only" function. Only the data
transmission speeds you specified with the wlan data rate-11abg command are used.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
The transmission standard IEEE 802.11a/b/g/n is set.
Syntax
Call the command without parameter assignment:
wlan data rates-11abg selected only
Result
The function is enabled.
Further notes
You display the setting with the show wlan data rates command.
You disable the function with the no wlan data rates-11abg selected only
command.
You configure the data transmission speeds with the wlan data rate-11abg command.
You configure the transmission standard with the wlan mode command.
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
232 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals