Result
The system time is set.
Further notes
You display the settings for the system clock with the show time command.
6.1.2.3 time dst date
Description
With this command, you configure the start and end of daylight saving time.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time dst date <name(16)> <year (1900-2099)> begin <MMDDhh> end
<MMDDhh>
The parameters have the following meaning:
Parameter Description Range of values / note
name Name of the entry maximum 16 characters
year Year 1900 ... 2099
begin Keyword for the start of daylight saving
time.
-
MMDDhh Time for the start of daylight saving time. Time in the format
MM Month
DD Day
hh Hour
end Keyword for the end of daylight saving
time.
-
MMDDhh Time for the end of daylight saving time. Time in the format
MM Month
DD Day
hh Hour
System time
6.1 System time setting
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
170 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals