The parameters have the following meaning:
Parameter Description Range of values / note
index Antenna connector X = 1
dB Attenuation in decibels [dB] 0...70
Default: 0
For information on names of addresses and interfaces, refer to the section "Interface identifiers
and addresses (Page 29)".
Result
The additional attenuation is specified.
Further notes
You show the set value with the show wlan antennas <wlan 0/X> command.
7.1.5.13 wlan antenna cable-length
Description
With this command, you configure the cable length between the SCALANCE W700 device
and the external antenna.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan antenna cable-length <index(1-2)> <m(0-30)>
The parameters have the following meaning:
Parameter Description Range of values / note
index Antenna connector 1...2
m Cable length in meters [m] 0...30
Default: 0
Result
The cable length is specified.
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
220 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals