Syntax
Call the command without parameter assignment:
no wlan data rates-11n selected only
Result
The function is disabled. The data transmission speed is adapted automatically.
Further notes
You display the setting with the show wlan data rates command.
You enable the function with the wlan data rates-11abg selected only command.
You configure the transmission standard with the wlan mode command.
7.1.5.31 wlan data rate-11abg (access point)
Description
With this command, you assign data transmission speeds to the required WLAN interface. The
access point will then use only the selected data transmission speeds for communication with
the clients.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
The transmission standard IEEE 802.11a/b/g/n is set.
The "Use selected data rates only" function is enabled.
Syntax
Call up the command with the following parameters:
wlan data rate-11abg {show-rates | {{add | del} <rate> | all | none}
[basic]}
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 235

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals