7.1.5.61 wlan rts-cts threshold
Description
With this command, you specify the packet size starting at which RTS/CTS (Request To Send/
Clear To Send) will be used.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan rts-cts threshold < bytes(1-2346)>
The parameter has the following meaning:
Parameters Description Range of values / note
bytes Size specified in bytes 1...2346
Default: 2346
Result
The packet size is specified.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.
7.1.6 Commands in the VAP Interface Configuration mode
This section describes commands that you can call up in the VAP Interface Configuration
mode. Depending on the Interface selected, various command sets are available.
In the Global Configuration mode, enter the interface vapX 0/Y command to change to
this mode.
If you exit the VAP Interface Configuration mode with the exit command, you return to
the Global Configuration mode.
If you exit the VAP Interface Configuration mode with the end command, you return to the
Privileged EXEC mode.
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 263

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals