Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameter assignment:
no alias
Result
The name of the interface is removed.
Further notes
You configure the name of the interface with the alias command.
4.1.11.3 duplex
Description
Electrical interfaces can be operated in full duplex mode or half duplex mode. The options here
depend on the connected device.
Optical connections are always operated in full duplex mode since they have a fiber for each
transmission direction.
With this command, you configure the duplex mode of an interface. The same mode must be
set for connected interfaces.
Requirement
Autonegotiation is disabled.
You are in the Interface configuration mode of an electrical interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
duplex {full|half}
Configuration
4.1 System
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
76 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals