11.1.4.8 no user-group
Description
With this command, you delete the link between a group and a role.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no user-group <user-group-name>
The parameter has the following meaning:
Parameter Description Range of values / note
user-group-name Group name Enter the name of a group.
Result
The link is deleted.
Further notes
You link a group with a role with the user-group command.
You show the created links with the show user-groups command.
11.1.4.9 username
Description
With this command, you change the password of the factory set default user "admin".
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Security and authentication
11.1 User rights management
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 485

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals