Result
The compatibility version of the protocol is selected.
Further notes
You can reset the setting to the default mst with the no spanning-tree
compatibility command.
You can display the status of this function and other information with the show spanning
tree detail command.
You can display information about active ports with the show spanning tree active
command.
7.3.3.4 no spanning-tree compatibility
Description
With this command, you reset the compatibility version of the protocol of the spanning tree
function to the default value.
The default value is MST.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree compatibility
Result
The compatibility version is reset to the default value.
Further notes
You configure the setting with the spanning-tree compatibility command.
You can display the status of this function and other information with the show spanning
tree detail command.
Network structures
7.3 Spanning Tree
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
312 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals