4.1.3 configure terminal
Description
With this command, you change to the Global configuration mode.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call the command without parameters:
configure terminal
Result
You are now in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Further notes
You exit the Global configuration mode with the end command.
4.1.4 clear line vty
Description
With this command, you close a console session on the device.
With the forceful-clear option, you close a session and that is not reacting.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Configuration
4.1 System
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
60 Configuration Manual, 09/2017, C79000-G8976-C324-08