The parameters have the following meaning:
Parameter Description Range of values / note
interface The interface that will be assigned to the
PRP network.
wlan 0/X
vap X 0/Y
network PRP Network A: PRP A
B: PRP B
-
enable: Enables iPRP
disable: Disables iPRP
Result
The iPRP function is configured.
Further notes
You display this setting and other information with the show wlan iprp information
command.
You remove the assignment with the command.
5.7.3.2 no wlan iprp interface
Description
With this command, you remove the assignment of the interface.
Requirement
You are in the WLAN iPRP configuration mode.
The command prompt is as follows:
cli (config-wlan-iprp-$)#
Syntax
Call up the command with the following parameters:
no wlan iprp interface <wlan 0/X | vap X 0/Y> network
The parameters have the following meaning:
Parameter Description Range of values / note
interface The interface that will be assigned to the
PRP network.
wlan 0/X
vap X 0/Y
Functions specific to SCALANCE
5.7 iPRP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
150 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals