7.1.5.47 no wlan force roaming eth-down (access point)
Description
With this command, you disable roaming if the connection aborts on the Ethernet interface.
This setting is activated as default.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
no wlan force roaming eth-down
Result
The function is disabled.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.
You enable the function with the wlan force roaming eth-down command.
7.1.5.48 wlan fragmentation threshold
Description
With this command, you specify the maximum packet size transferred on the wireless link.
Large packets are divided up into small packets prior to transmission and then reassembled
into the original size after they have been received.
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
250 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals