Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
If you exit the EVENTS configuration mode with the exit command, you return to the
Global configuration mode.
If you exit the EVENTS configuration mode with the end command, you return to the
Privileged EXEC mode.
12.2.2.1 syslogserver
Description
With this command, you configure the Syslog server.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
syslogserver { ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6
<ip6_addr>} [<port(1-65535)>]
The parameters have the following meaning:
Parameter Description Range of values / note
ipv4 Keyword for an IPv4 address -
ucast_addr IPv4 unicast address of the Syslog serv‐
er
Enter a valid IPv4 address.
fqdn-name Keyword for a domain name -
FQDN Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
If you have stored a suitable do‐
main name, you can specify a host
name.
ipv6 Keyword for an IPv6 address -
ip6_addr IPv6 address of the Syslog server Enter a valid IPv6 address.
port Port of the Syslog server on which the
messages are received
0 … 65535
Default: 514
For information on names of addresses and interfaces, refer to the section "Interface identifiers
and addresses (Page 29)".
If you do not select any parameters from the parameter list, the default value is used.
Diagnostics
12.2 Syslog client
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
604 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals