Syntax
Call the command without parameters:
no telnet-server
Result
The Telnet server is disabled.
Further notes
You enable the Telnet server with the telnet-server command.
8.1.2.3 ip echo-reply
Description
To check the availability of a network node, packets of the Internet Control Message Protocol
(ICMP) can be sent to it. These packets of type 8 request the recipient to send a packet back
to the sender (echo reply).
With this command you enable the network node to react to ping queries.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
ip echo-reply
Result
"ICMP echo reply messages" are enabled. The network node reacts to ping queries.
Further notes
You disable the setting with the no ip echo-reply command.
Network protocols
8.1 IPv4 protocol
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 347

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals