Result
The link local address is deleted.
Further notes
You assign a link local address to an IP interface with the command ipv6 address link-
local.
You display this setting and other information with the show ipv6 interface command.
8.2.4.9 ipv6 enable
Description
With this command, you enable IPv6 on the interface. As default, IPv6 is disabled.
Requirement
IPv6 routing is activated
The interface is an IP interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Requirement
You are in the Interface configuration mode of VLAN.
The command prompt is as follows:
cli(config-if-vlan-$$$)#
Syntax
Call the command without parameter assignment:
ipv6 enable
Result
IPv6 is enabled.
Further notes
You configure an IPv6 address with the ipv6 address command.
You display this setting and other information with the show ipv6 interface command.
You enable IPv6 routing with the ipv6 unicast-Routing command.
Network protocols
8.2 IPv6 protocol
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 377

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals