12.1.6.12 severity
Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog | authlog } { info | warning |
critical }
The parameters have the following meaning:
Parameter Description Range of values / note
mail System event messages are sent by e-
mail.
-
log System event messages are entered in
the log table.
-
syslog System event messages are entered in
the syslog file.
-
authlog System event messages are entered in
the log table for authentications.
-
info System events are processed as of the
severity level "Information".
-
warning System events are processed as of the
severity level "Warning".
-
critical System events are processed as of the
severity level "Critical".
-
Result
The settings for sending system event messages are configured.
The "severity" function is enabled.
Further notes
You disable the setting with the no severity command.
You display the status of this function and other information show events severity
Diagnostics
12.1 Diagnostics
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 601

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals