Syntax
Call up the command with the following parameters:
spanning-tree[mst <instance-id(1-64)>] priority <value(0-61440)>
The parameters have the following meaning:
Parameter Description Range of values / note
mst Keyword for a Multiple Spanning Tree
instance
-
instance-id Number of the instance 1 ... 64
priority Keyword for the priority -
value Value for the priority 0 ... 61440
Default: 32768
You can only change the value for the priority in the steps of 4096.
Result
The priority of the device is configured.
Further notes
You can reset the setting to the default with the no spanning-tree priority command.
You display this setting and other information with the commands that start with show
spanning-tree ....
7.3.3.15 no spanning-tree priority
Description
With this command, you reset the priority of the device back to the default value.
The default value is 32768.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no spanning-tree[mst <instance-id(1-64)>]priority
Network structures
7.3 Spanning Tree
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
320 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals