Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
The transmission standard IEEE 802.11n or IEEE 802.11n only is set.
Syntax
Call the command without parameter assignment:
wlan data rates-11n selected only
Result
The function is enabled.
Further notes
You display the setting with the show wlan data rates command.
You disable the function with the no wlan data rates-11n selected only command.
You configure the data transmission speeds with the wlan data rate-11n command.
You configure the transmission standard with the wlan mode command.
7.1.5.30 no wlan data rates-11n selected only (access point)
Description
With this command, you enable / disable the automatic selection of the data transmission
speed.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
The transmission standard IEEE 802.11n or IEEE 802.11n only is set.
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
234 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals