Requirement
IPv6 is activated
The interface is an IP interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call the command without parameter assignment:
no ipv6 address dhcp
Result
DHCPv6 is disabled.
Further notes
You enable DHCPv6 with the ipv6 address dhcp command.
You configure the interface as a router port with the no switchport command.
You show the setting with the show ipv6 dhcp interface command.
You can display the statistics of the DHCPv6 client with the show ipv6 dhcp client
statistics command.
8.2.4.7 ipv6 address link-local
Description
With this command, you assign a link local address to the interface.
Requirement
IPv6 is activated
The interface is an IP interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
ipv6 address <prefix> link-local
Network protocols
8.2 IPv6 protocol
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 375

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals