The interface is an IP interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
no ipv6 dhcp client request {dns-server-address | domain-name | sntp-
server-address | option <code (1-100)>}
The parameters have the following meaning:
Parameter Description Range of values / note
dns-server-
address
IPv6 address of the DNS server -
domain-name Domain name -
sntp-server-
address
IPv6 address of the SNTP server -
option Keyword for the option code -
code ID of the DHCPV6 option Specify the required ID of the
DHCPv6 option.
1 ... 100
Result
The required configuration parameter is removed.
Further notes
You configure the request with the ipv6 dhcp client request command.
8.5 DHCP server
You can operate the device as a DHCP server. This allows IP addresses to be assigned
automatically to the connected devices. The IP addresses are either distributed dynamically
from an address band (pool) you have specified or a specific IP address is assigned to a
particular device.
Network protocols
8.5 DHCP server
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 387

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals