The parameters have the following meaning:
Parameter Description Range of values / note
v3only Only SNMPv3 queries are processed -
all All SNMP queries are processed Default: all
Result
The setting is configured.
8.6.2.4 snmp access
Description
With this command, you configure the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName> {v1|v2c|v3 {auth|noauth|priv}}
[read <ReadView|none>][write <WriteView|none>][notify <NotifyView|
none>]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter Description Range of values / note
GroupName Name of the group to which access is
configured
max. 32 characters
Version Selects the version of the protocol used
v1
v2c
v3
Authentication Selects the authentication method.
auth
Enables MD5 or SHA as
authentication method
noauth
No authentication
priv
Enables authentication and
encryption
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 415

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals