Requirement
The PLUG is formatted.
You are in the Plug Configuration mode.
The command prompt is:
cli(config-plug)#
Syntax
Call the command without parameter assignment:
write
Result
The current device configuration has been copied to the formatted PLUG.
5.1.3.5 presetplug
Description
With this command, you create a PRESET-PLUG. Apart from the configuration data, a
PRESET-PLUG also contains the firmware version of the creating device. The PRESET PLUG
is write-protected.
I a device starts with a PRESET-PLUG an upgrade/downgrade of the firmware is performed
if there is a different firmware version on the device. This is indicated by the red LED flashing
(flashing interval: 2 sec on/0.2 sec off). Afterwards the device is restarted and the device
configuration incl. users and certificates on the PRESET-PLUG is transferred to the device.
To make the PLUG writable again, call the command factoryclean.
Requirement
The PLUG is formatted.
There is a device configuration on the PLUG.
You are in the Plug Configuration mode.
The command prompt is:
cli(config-plug)#
Syntax
Call the command without parameter assignment:
presetplug
Result
The firmware of the executing device is written to the PLUG and write-protected.
Functions specific to SCALANCE
5.1 PLUG
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 113

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals