The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan background scan threshold <dBm(-95-0)>
The parameter has the following meaning:
Parameters Description Range of values / note
ms Threshold value in deci‐
bel-milliwatts (dBm)
-95 ... 0
Result
The threshold value is specified.
Further notes
You display the setting with the show wlan client <wlan 0/X> command.
7.1.5.23 wlan beacon interval (access point)
Description
With this command, you specify the interval at which the SCALANCE W700 device sends
beacons. Beacons are packets that are sent cyclically by an access point to inform clients of
its existence.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan beacon interval <ms(40-1000)>
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
228 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals