Client mode: Client with KEY-PLUG W740 iFeatures (MLFB 6GK5 907-4PA00)
The management interface and data interface must be operated in the same frequency
band and mode and must match in terms of their wireless coverage. iPCF-MC will not work
if both wireless interfaces are equipped with directional antennas that cover different areas.
The management interfaces of all access points to which a client can change must use the
same channel. A client scans only this one channel to find accessible access points.
Transmission based on IEEE801.11h (DFS) cannot be used for the management interface.
801.11h (DFS) is possible for the data interface.
The client cannot be operated with "Use Allowed Channel only".
"Force roaming on Ethernet down" is automatically mirrored on the second interface.
The following applies to clients: All configured and active SSIDs must be assigned to
security context 1. An SSID is active when the corresponding check box "Enabled" is
selected on the page "Interfaces > WLAN > Client".
In Japan, iPCF-MC cannot be enabled if the data or management interface uses a
frequency of the 4920 MHz - 5080 MH frequency band.
Syntax
Call the command without parameter assignment:
wlan ipcf-mc
Result
iPCF-MC is enabled.
Further notes
You disable iPCF-MC with the no wlan ipcf-mc command.
You display the setting with the show wlan ipcf-mc command.
5.6.2.2 no wlan ipcf-mc
Note
The command is only available if the SCALANCE W700 device supports iPFC-MC or the
function can be enabled.
iPCF-MC is enabled with the aid of the following KEY-PLUGs:
W780 iFeatures (MLFB 6GK5 907-8PA00)
W740 iFeatures (MLFB 6GK5 907-4PA00)
Description
With this command, you disable iPCF-MC on this SCALANCE W700 device.
Functions specific to SCALANCE
5.6 iPCF-MC
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 141

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals