12.1.6.13 no severity
Description
With this command, you disable the setting for the threshold values for the sending of system
event notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
no severity { mail | log | syslog | authlog }
The parameters have the following meaning:
Parameter Description Range of values / note
mail The setting of the threshold value for
sending system event messages by e-
mail is disabled.
-
log The setting of the threshold value for
entering system event messages in the
log table disabled.
-
syslog The setting of the threshold value the
entering event messages in the Syslog
file is disabled.
-
authlog The setting of the threshold value for
entering system event messages in the
log table for authentications is disabled.
-
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for sending system event messages are configured.
Further notes
You enable the setting with the severity command.
You display the status of this function and other information show events severity.
Diagnostics
12.1 Diagnostics
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
602 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals