4.1.6 enable
Description
With this command, you change to the Privileged EXEC mode.
Requirement
You are in the User EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call the command without parameters:
enable
Result
You are prompted to enter the administrator password. After logging in successfully, you are
in the Privileged EXEC mode.
The command prompt is as follows:
cli#
4.1.7 logout
Description
With this command, you exit the Command Line Interface.
If you are connected to the device via telnet, the session is closed.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
logout