4.2.5.2 tftp filename
Description
With this command, you assign a name to a file type.
The file type decides the type that is affected by the tftp load or tftp save action. The
name decides the file to be copied to or from the TFTP server.
Requirement
You are in the LOADSAVE configuration mode.
The command prompt is as follows:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp filename {showfiles|filetype< filetype >name<filename>}
The parameters have the following meaning:
Parameter Description Range of values / note
showfiles Shows the available files -
filetype Keyword for a file type to be assigned a
name
-
filetype Name of the file type max. 100 characters
name Keyword for a file name to be assigned
to the file type
-
filename Name of the file max. 100 characters
Result
The file types are displayed or the file type is assigned a name.
Further notes
With the "show loadsave files" command, you can display the file types.
4.2.5.3 tftp load
Description
With this command, you load a file from a TFTP server into the file system of the device. The
TFTP protocol is used for the transfer. You can also display a list of available files.
Configuration
4.2 Load and Save
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
90 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals