Result
The number of measurements is specified.
Further notes
You display the setting with the show wlan ipcf-mc command.
You disable the setting with the no wlan ipcf-mc roaming-filter command.
5.6.2.7 no wlan ipcf-mc roaming-filter (client)
Note
The command is only available if the SCALANCE W700 device supports iPFC-MC or the
function can be enabled.
iPCF-MC is enabled with the aid of the following KEY-PLUGs:
W780 iFeatures (MLFB 6GK5 907-8PA00)
W740 iFeatures (MLFB 6GK5 907-4PA00)
Description
With this command, you disable the roaming filter.
Requirement
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call the command without parameter assignment:
no wlan ipcf-mc roaming-filter
Result
The roaming filter is disabled.
Further notes
You display the setting with the show wlan ipcf-mc command.
You enable the roaming filter with the wlan ipcf-mc roaming-filter command.
Functions specific to SCALANCE
5.6 iPCF-MC
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
146 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals