Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp notify <NotifyName> tag <TagName> type {Trap|Inform}
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter Description Range of values / note
NotifyName Name of the SNMP notification max. 32 characters
tag Keyword for a target key -
TagName Name of the target key max. 32 characters
Type Type of the SNMP notification
Trap
Generates a trap.
Inform
Generates a log entry or sends
an entry to the log server.
Storage type Specifies whether the settings remain
following a restart.
:
The settings are lost after a
restart
:
The settings are retained after
a restart
Result
The details of the SNMP notifications are configured.
Further notes
You delete the details of an SNMP notification with the no snmp notify command.
You display the configured SNMP notifications with the show snmp notif command.
You display the configured SNMP target addresses with the show snmp targetaddr
command.
8.6.2.15 no snmp notify
Description
With this command, you delete the details of the SNMP notifications.
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 425

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals