The parameters have the following meaning:
Parameter Description Range of values / note
radius The login is via a RADIUS server. -
local-and-radius The login is possible both with the users
that exist in the firmware (user name
and password) and via a RADIUS serv‐
er.
The local users have priority.
The user is first searched for in the
local database. If the user does not
exist there, a RADIUS query is sent.
radius-fallback-
local
The authentication must be handled via
a RADIUS server.
A local authentication is performed
only when the RADIUS server can‐
not be reached in the network.
Result
The authentication is made according to the selected parameter.
Further notes
You disable the authentication via a RADIUS server with the no login authentication
command.
You can display the status of this function and other information with the show device
information command.
11.2.2.2 no login authentication
Description
With this command, you disable authentication via a RADIUS server.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
no login authentication
Security and authentication
11.2 RADIUS client
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
490 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals