7.1.7.3 wds partner wds-id (access point)
Description
With this command, you enter the WDS ID of the WDS partner.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode for the WDS interface.
The command prompt is as follows:
cli (config-if-wdsX-0-Y)#
Syntax
Call up the command with the following parameters:
wds partner wds-id <wds-id>
The parameter has the following meaning:
Parameters Description
wds-id WDS ID of the WDS partner
Result
The WDS ID is specified.
Further notes
You display the setting with the show wlan wds <wdsX 0/Y> command.