The filter is created.
Further notes
You delete a filter with the no snmp filterprofile command.
You display the created filter with the show snmp filter table command.
8.6.2.11 no snmp filterprofile
Description
With this command, you delete a filter.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp filterprofile <profilename><OIDTree>
The parameters have the following meaning:
Parameters Description Range of values / note
profilename Name of the filter profile max. 32 characters
OIDTree Object ID Path information of the MIB tree
Result
The filter is deleted.
Further notes
You create a filter with the snmp filterprofile command.
You display the created filter with the show snmp filter table command.
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
422 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals