Loading...
Result
The filter is created.
Further notes
You delete a filter with the no snmp filterprofile command.
You display the created filter with the show snmp filter table command.
8.6.2.11 no snmp filterprofile
Description
With this command, you delete a filter.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp filterprofile <profilename><OIDTree>
The parameters have the following meaning:
Parameters Description Range of values / note
profilename Name of the filter profile max. 32 characters
OIDTree Object ID Path information of the MIB tree
Result
The filter is deleted.
Further notes
You create a filter with the snmp filterprofile command.
You display the created filter with the show snmp filter table command.
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
422 Configuration Manual, 09/2017, C79000-G8976-C324-08