Syntax
Call up the command with the following parameters:
ntp server { ipv4 <ip_addr> | fqdn-name <Fully Qualified Domain
Name(100)> | ipv6 <ip6_addr> } [port { <1025-36564> | default}] [poll
<seconds(64-1024)>]
The parameters have the following meaning:
Parameter Description Range of values / note
id Number of the NTP server. 1 … 4
ipv4 Keyword for an IPv4 address -
ip_addr Value for the IPv4 address of the time
server
Enter a valid IPv4 address.
fqdn-name Keyword for a domain name -
FQDN Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
If you have stored a suitable do‐
main name, you can specify a host
name.
ipv6 Keyword for an IPv6 address -
ip6_addr Value for the IPv6 address of the time
server
Enter a valid IPv6 address.
port UDP port of the time server 1025 … 36564
default Default value for the UDP port 123
poll Keyword for the time after which the
time of day is requested again
-
seconds Value for the time in seconds 64 … 1024
For information on identifiers of addresses and interfaces, refer to the section "Addresses and
interface identifiers (Page 29)".
Result
The connection to a server is configured on the NTP client.
Further notes
You delete the connection to a server with the no ntp server command.
You store a domain name with the ip domain name or domain name command.
6.2.3.2 no ntp server
Description
With this command, you delete the connection to a server on the NTP client.
System time
6.2 NTP client
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 175

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals