7.1.5.46 wlan force roaming eth-down (access point)
Description
If the wired Ethernet interface is no longer available (cable break, connector removed), a client
connected over the wireless network is not aware of this.
The access point can force the logged-on clients to roam by deactivating its WLAN interface.
The client then attempts to log on at a different access point. With this command, you enable
this function.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
wlan force roaming eth-down
Result
The function is enabled.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.
You disable the function with the no wlan force roaming eth-down command.
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 249

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W770 Series and is the answer not in the manual?

Siemens SCALANCE W770 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W770 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals