You show the NAT configuration and the translation list with the show nat command.
10.1.3.7 no nat interface (Client)
Note
This command is only available in the client mode.
Description
With this command, you disable NAT.
Requirement
You are now in the NAT Configuration mode.
The command prompt is as follows:
cli(config-nat)#
Syntax
Call the command without parameters:
no nat interface
Result
NAT is disabled.
Further notes
You enable NAT with the nat interface command.
See also
show nat (Client) (Page 456)
10.1.3.8 nat ipv4 multicast forward global-to-local (Client)
Note
This command is only available in the client mode.
Layer 3 functions
10.1 NAT
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
464 Configuration Manual, 09/2017, C79000-G8976-C324-08